Inventory all parts received from the laboratory immediately after arrival of the case in the office. Are the correct number of final screws included and are they in the original packaging? Assemble the restoration on the working model using only one screw in a terminal implant. Hand tighten the screw and examine if the restoration seats passively on all implants with just one screw tightened. Ensure all screws pass through the access channels without binding.
Torque wrench
Intermediary abutment
In most instances it is not necessary to anesthetize the patient for the delivery of the restoration unless tissue recontouring around the implants is planned. Remove any temporary restorations, temporary abutments or trans mucosal healing abutments. Irrigate the inside of the implant with chlorhexidine and flush out any debris.
Place the hybrid denture in the patients mouth on to the implants, using only one screw in a terminal implant. Hand tighten the screw and examine if the restoration seats passively on all implants with just one screw tightened. After passive fit of the restoration is confirmed in the patients mouth, hand tighten the remaining screws. Take a panograph to ensure all components are seated and as a bone level baseline record. Adjust occlusion and equalize lateral contacts. Torque all screws with the torque wrench to implant manufacturers specification. Wait a few minutes and torque the screws again to specification. Place a small cotton ball in to each screw access channel to protect the hex of the screw and fill with composite.