Implant Direct™ Surgical Tools

Torque Wrench

Fig. 1

A multi torque setting wrench (Fig.1, catalog # TWM) is offered from Implant Direct™. The multi torque setting wrench can be adjusted to nine (15, 20, 25, 30, 35, 40, 45, 50 and 60 Ncm) different torque settings.

Drill Extender

The latch type drill extender (catalog # DE) may be used with any latch type drill or driver.

Fixture Mount Driver

Fig. 2

The latch type fixture mount driver (Fig.2, catalog # FMD) is used to pick up the implant from the packaging, carry the implant to the surgical site and drive the implant in to the osteotomy for Legacy™ II and III, ReActive®, RePlant®, RePlus®, SwishPlant™ (SwissPlant™), Spectra-System® (ScrewPlant®, ScrewPlus®) implants. The same fixture mount driver is utilized regardless of the implant diameter.

Legacy™ (I, II, III)

Drivers

Fig. 3

1.25mm hex drivers are available for torque wrenches as a long (Fig.3 left, catalog # HT1.25) and short (Fig.3 right, catalog # HT1.25S) version and a latch type driver (Fig.6 "A", catalog # HD1.25) for surgical units is produced in one length. The 1.25mm hex driver engages the abutment screw to loosen or tighten the fixture mount and abutments.

2mm hex drivers are available for torque wrenches as a long (Fig.4 left, catalog # HT2.0) and short (Fig.4 right, catalog # HT2.0S) version and a latch type driver (Fig.6 "B", catalog # HD2.0) for surgical units is produced in one length. The 2mm hex driver engages Legacy™ III 3.2mm diameter implant directly without the fixture mount in place for delivery.

Fig. 4

2.5mm hex drivers are available for torque wrenches as a long (Fig.5 left, catalog # HT2.5) and short (Fig.5 right, catalog # HT2.5S) version and a latch type driver (Fig.6 "C", catalog # HD2.5) for surgical units is produced in one length. The 2.5mm hex driver engages any of the titanium fixture mounts and Legacy™ implant/abutment platform of 3.5, 4.5mm directly, without the fixture mount in place.

3mm hex drivers are available for torque wrenches as a long (Fig.8 left, catalog # HT3.0) and short (Fig.8 right, catalog # HT3.0S) version and a latch type driver (Fig.6 "D", catalog # HD3.0) for surgical units is produced in one length. The 3mm hex driver engages the implant/abutment platform of all 5.7mm Legacy™ implants without the fixture mount in place.

ReActive®, RePlant®, RePlus®

Drivers

1.25mm hex drivers are available for torque wrenches as a long (Fig.3 left, catalog # HT1.25) and short (Fig.3 right, catalog # HT1.25S) version and a latch type driver (Fig.6 "A", catalog # HD1.25) for surgical units is produced in one length. The 1.25mm hex driver engages the abutment screw to loosen or tighten the fixture mount and abutments.

Fig. 5

2.5mm hex drivers are available for torque wrenches as a long (Fig.5 left, catalog # HT2.5) and short (Fig.5 right, catalog # HT2.5S) version and a latch type driver (Fig.6 "C", catalog # HD2.5) for surgical units is produced in one length. The 2.5mm hex driver engages any of the titanium fixture mounts, regardless of implant diameter.

SwishPlant™ (SwissPlant™)

Drivers

Fig. 6

1.25mm hex drivers are available for torque wrenches as a long (Fig.3 left, catalog # HT1.25) and short (Fig.3 right, catalog # HT1.25S) version and a latch type driver (Fig.6 "A", catalog # HD1.25) for surgical units is produced in one length. The 1.25mm hex driver engages the abutment screw to loosen or tighten the fixture mount and abutments.

2.5mm hex drivers are available for torque wrenches as a long (Fig.5 left, catalog # HT2.5) and short (Fig.5 right, catalog # HT2.5S) version and a latch type driver (Fig.6 "C", catalog # HD2.5) for surgical units is produced in one length. The 2.5mm hex driver engages any of the titanium fixture mounts directly for pick up and delivery of the implant, regardless of implant diameter.

Fig. 7

Insertion Tool (Fig.7 left, catalog # 9048-07) is offered in one length for the torque wrench only. The insertion tool engages the implant directly without the fixture mount in place.

Octagon Alignment Tool (Fig.7 right, catalog # OCTT) is offered in one length for the torque wrench only. This tool is used to align one of the flat sides of the internal octagon with the labial or buccal.

Spectra-System®

ScrewPlant® ScrewPlus®

Drivers

1.25mm hex drivers are available for torque wrenches as a long (Fig.3 left, catalog # HT1.25) and short (Fig.3 right, catalog # HT1.25S) version and a latch type driver (Fig.6 "A", catalog # HD1.25) for surgical units is produced in one length. The 1.25mm hex driver engages the abutment screw to loosen or tighten the fixture mount and abutments.

2.5mm hex drivers are available for torque wrenches as a long (Fig.5 left, catalog # HT2.5) and short (Fig.5 right, catalog # HT2.5S) version and a latch type driver (Fig.6 "C", catalog # HD2.5) for surgical units is produced in one length. The 2.5mm hex driver engages any of the titanium fixture mounts and ScrewPlant®/ScrewPlus® implant/abutment platform of 3.5, 4.5mm directly, without the fixture mount in place.

Fig. 8

3mm hex drivers are available for torque wrenches as a long (Fig.8 left, catalog # HT3.0) and short (Fig.8 right, catalog # HT3.0S) version and a latch type driver (Fig.6 "D", catalog # HD3.0) for surgical units is produced in one length. The 3mm hex driver engages the implant/abutment platform of all 5.7mm and 6.5mm implant diameter ScrewPlant®/ScrewPlus® implants without the fixture mount in place.

ScrewDirect®ScrewRedirect™

Drivers

2mm hex drivers are available for torque wrenches as a long (Fig.4 left, catalog # HT2.0) and short (Fig.4 right, catalog # HT2.0S) version and a latch type driver (Fig.6 "B", catalog # HD2.0) for surgical units is produced in one length. The 2mm hex driver engages abutment portion of the implant directly for delivery.

Screwindirect®
GoDirect™